B2B online shop for companies, self-employed professionals and public institutions · Become a KERN customer now!
The article could not be placed in the shopping cart. Please try again.
Current service information
  • Sound Level Meter SAUTER SW 1000 / SW 2000 Main picture
  • Sound Level Meter SAUTER SW 1000 / SW 2000 Detail picture Front view
  • Sound Level Meter SAUTER SW 1000 / SW 2000 Detail picture Scope of delivery
  • Sound Level Meter SAUTER SW 1000 / SW 2000 Detail picture
  • Sound Level Meter SAUTER SW 1000 / SW 2000 Detail picture
  • Sound Level Meter SAUTER SW 1000 / SW 2000 Detail picture
  • Sound Level Meter SAUTER SW 1000 / SW 2000 Detail picture Top side

Sound Level Meter
SW 1000

Product family: SW

Professional Class I sound level meter in premium quality

Technical Data

Measuring range Sound 20 dB – 134 dB
Readability sound [d] (dB) 0,1 dB
Units dB
Sound level measuring modes Lp, Leq, Ln, Lcpeak
Sound level methods of evaluation A, C, Z, B
Frequency range 10 Hz – 20 kHz

more data

Your price
€ 2.100,00 *
*plus shipping costs
(excluding downloads), plus VAT
Available on stock
Compare Technical data sheet Product brochure Download centre

Standard

Peak hold function: capturing a peak value within a measuring process
Memory: Device-internal memory capacity, e.g. for article data, measuring data, tare weights, PLU etc.
Data interface RS-232:  For connection to printers, PCs or other peripheral devices for data transfer over longer distances. Network in bus topology possible
Data Interface USB: For connection to printers, PCs or other peripheral devices
Analogue interface: to connect a suitable peripheral device for analogue processing of the measurements
Statistics: using the saved values, the device calculates statistical data, such as average value, standard deviation etc.
Measuring with tolerance range (checkweighing): Upper and lower limit values can be programmed, e.g. for sorting, portioning or for measuring coatings or material thicknesses. The process is supported by an acoustic and/or optical signal
Battery operation: Ready for battery operation
External power adapter: EU standard as standard. Optional accessories available for UK, US, AUS and others
Package shipment by courier service: The duration of internal product provision is one day

Option

PC Software: to transfer the measurements from the device to a PC
Factory calibration (ISO): Factory calibration takes 4 working days
Accredited calibration (DKD): The duration of the accredited calibration is 3 working days

Do you have questions?

We will be happy to consult you on our SAUTER measuring devices

Tel.: +49 7433 9933-562

info.sauter@kern-sohn.com

Service hotline for all technical questions about our SAUTER measuring instruments

Tel.: +49 7433 9933-555

Description

  • Ideal for measurements for workplaces outdoor, e.g. at airports, on building sites, in road traffic etc. with wide frequency access
  • Modern microcontroller architecture for increased stability and accuracy
  • A specially-developed algorithm permits a compliant dynamic range of > 123 dB
  • Three profiles and 14 user-defined measurements can be calculated in parallel with different frequency and time weighting
  • LN statistics and display of the graph showing the progression of time
  • User-defined integral interval measurement up to a maximum of 24 hours is possible
  • Frequency weighting (filter) A, B, C, Z
  • Time interval during measurement: F (fast), S (slow), I (pulse)
  • Freely-definable limits for the output of an optical alarm signal
  • Peak Hold function to capture peak value
  • Octave function for targeted sound analysis, can be expanded to 1/3 octave through the purchase of a licence
  • TRACK function with graphic display of a measurement
  • Calibration mode (with optional calibrator)
  • Trigger mode: external start/stop of measurement via 3,5 mm connector
  • Automatic measurement for timer function is possible
  • Operating languages: EN, DE, FR, ES, PT
  • Option of fitting a stand on the rear of the housing, ¼" thread
  • Delivery in robust transport case

Applications

Main fields of application / Primary application areas

  • Occupational safety and industry
  • Construction and building sites
  • Event and sound technology
  • Environmental protection
  • Research and development
  • Technical test centres and experts
  • Acoustic laboratories

Technical Data

Measuring range Sound 20 dB – 134 dB
Readability sound [d] (dB) 0,1 dB
Units dB
Sound level measuring modes Lp, Leq, Ln, Lcpeak
Sound level methods of evaluation A, C, Z, B
Frequency range 10 Hz – 20 kHz
Sound level meter class Class 1
Memory function
Hold function
Peak function
Limit-setting function
Microphone sensitivity 50 mV/Pa
Battery 4×1.5 V AA
Material housing plastic
Dimensions completely mounted (W×D×H) 340×80×40 mm
Product family SW
Frequency range [Min] 10 Hz
Frequency range [Max] 20 kHz
Warranty Time 36 mon
GTIN/EAN number 4045761200845

Accessories

Software

Services